Siemens SIMATIC IPCs
VulnView CSAF Summary The products listed below contain a vulnerability that could allow an attacker to boot an operating system or UEFI application signed with that test key, bypassing UEFI Secure Boot protections even when Secure Boot is enabled. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens SIMATIC IPCs are affected: SIMATIC IPC BX-21A vers:intdot/<31.01.13 (CVE-2026-72895) SIMATIC IPC RW-543A vers:intdot/<1.1.4 (CVE-2026-72895) SIMATIC IPC227G / IPC277G / IPC277G PRO / IPC327G / IPC377G vers:intdot/<28.01.15 (CVE-2026-72895) CVSS Vendor Equipment v3 7.7 Siemens SIMATIC IPC BX-21A 1 Vulnerability Use of Default Cryptographic Key Background Critical Infrastructure Sectors: Critical Manufacturing, Transportation Systems, Energy, Healthcare and Public Health, Financial Services, Government Services and Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities CVE-2026-72895 A BIOS vendor test key is present in the UEFI Secure Boot key database. This could allow a local attacker with physical or administrative access to the device to boot an operating system or UEFI application signed with that test key, bypassing UEFI Secure Boot protections even when Secure Boot is enabled, potentially leading to a full loss of confidentiality, integrity, and availability of the device. Read More 3 Affected Products SIMATIC IPC BX-21A < V31.01.13 Product Status: known_affected Remediations MitigationNote: After upgrading to the fixed BIOS version, users must load the BIOS default settings. If Secure Boot keys were already provisioned, they must be provisioned again afterwards. MitigationAs a temporary mitigation, users can manually remove the test key from the database (e.g., "DO NOT TRUST - AMI Test PK" for RW-543A or "insyde-ElkhartLake" for IPC227G/277G/327G/377G and BX-21A). Note: Loading default settings will restore the test key, so upgrading remains recommended. Vendor fixUpdate to V31.01.13 or later version SIMATIC IPC RW-543A < V1.1.4 Product Status: known_affected Remediations MitigationNote: After upgrading to the fixed BIOS version, users must load the BIOS default settings. If Secure Boot keys were already provisioned, they must be provisioned again afterwards. MitigationAs a temporary mitigation, users can manually remove the test key from the database (e.g., "DO NOT TRUST - AMI Test PK" for RW-543A or "insyde-ElkhartLake" for IPC227G/277G/327G/377G and BX-21A). Note: Loading default settings will restore the test key, so upgrading remains recommended. Vendor fixUpdate to V1.1.4 or later version SIMATIC IPC227G / IPC277G / IPC277G PRO / IPC327G / IPC377G < V28.01.15 Product Status: known_affected Remediations MitigationNote: After upgrading to the fixed BIOS version, users must load the BIOS default settings. If Secure Boot keys were already provisioned, they must be provisioned again afterwards. MitigationAs a temporary mitigation, users can manually remove the test key from the database (e.g., "DO NOT TRUST - AMI Test PK" for RW-543A or "insyde-ElkhartLake" for IPC227G/277G/327G/377G and BX-21A). Note: Loading default settings will restore the test key, so upgrading remains recommended. Vendor fixUpdate to V28.01.15 or later version Additional Metrics Relevant CWE: CWE-1394 Use of Default Cryptographic Key CVSS Version Base Score Base Severity Vector String 3.1 7.7 HIGH CVSS:3.1/AV:L/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H View CVE Details Acknowledgments Siemens ProductCERT reported this vulnerability to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-159454 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-10-13 Date Revision Summary 2026-10-13 1 Publication Date 2026-10-22 2 Initial CISA Republication of Siemens ProductCERT SSA-159454 advisory Legal Notice and Terms of Use
Read full story at CISA Advisories →